Results
What each project has measured so far, with the examples behind the numbers. Misses and caveats are included.
rwfsas · perimeter estimation
Each test takes a mapped fire perimeter, feeds the model only the satellite detections from the following window, and scores the predicted new growth against the next mapped perimeter. Growth IoU counts only area outside the starting perimeter, so keeping the old footprint earns nothing. Release target: 85% acreage accuracy and 0.65 IoU on steps where the fire more than triples in size.
- 0.45best growth IoU, explosive steps (learned field v3)
- 0.65release target
- 0.979per-cell AUC: the field ranks burned cells well
- 759replay steps, 69,284 GOES granules

| Method | Growth IoU |
|---|---|
| Detection-driven baseline (“champion”) | 0.21 |
| Learned field v2, learned area multiplier | 0.43 |
| Learned field v3, best operating point | 0.45 |
| Oracle area cutoff (uses the true answer; not deployable) | 0.50 |

Where it falls short
- The field ranks cells well, but no tested selector reliably knows how much area to keep on the most explosive steps. With the true area known, growth IoU rises to 0.53 and acreage accuracy to about 88%.
- On 116 explosive steps, the live dual-GOES champion scored a median growth IoU of 0.213, acreage error 0.306, recall 0.307 and precision 0.483.
- A 2 km GOES pixel is roughly 1,000 acres, so small fires that stay inside one tile are hard to trace. Larger fires score better.
- No five-minute reference truth set exists yet, so the live five-minute loop has no accuracy number.
Source: rwfsas v0.1 documentation. rwfsas on GitHub
rwfds · camera smoke detection
The current detector reads each camera frame together with what the camera saw over the previous 20 minutes. It sees what changed, not just what looks like smoke, and its output includes a map of where in the frame it thinks the smoke is. It is tested on HPWREN’s Fire Ignition Library: fixed mountaintop cameras, one frame a minute, from 40 minutes before to 40 minutes after HPWREN’s “first visible plume” mark (0 min).
- 89.5%frame accuracy on 62 held-out fires (best published: 84.7%)
- 62 / 62fires detected by the end of the sequence
- 94.1%precision (published: 88.7%)
- 1.83 minmean time to detection (c4, published: 2.26)

| Model | Acc. | F1 | Prec. | Recall | TTD |
|---|---|---|---|---|---|
| rwfds c3d, 3-seed ensemble | 89.45 | 89.01 | 94.09 | 84.45 | 2.39 |
| rwfds c4, with outline loss | 88.75 | 88.58 | 91.03 | 86.27 | 1.83 |
| rwfds c3e, only SmokeyNet’s own training fires | 85.96 | 86.43 | 84.60 | 88.34 | 1.78 |
| ContrastSwin, 2-frame (2023) | 84.67 | 84.05 | 88.74 | 79.83 | 2.26 |
| SmokeyNet, 3-frame (2022) | 83.62 | 82.83 | 90.85 | 76.11 | 2.94 |
TTD is the mean minutes after the 0 mark until the first positive frame, over detected fires; lower is faster. Run 20–21 Oct 2026 on SmokeyNet’s published split. Models start from public ImageNet weights, and every test run is logged, including ones that didn’t help. The headline model was picked on validation fires only.
Against the time each fire was first reported, c3d’s first alert came earlier on 19 of 29 matched camera views (median lead +3.1 min). Six of those matches are probably name mismatches; without them it is 14 of 23, with a median lead of +0.8 min. Most of the late views were placed so that HPWREN’s own first-visible mark already came 7–12 minutes after the report.
Where it falls short
- The frame label is purely time-based (positive from 0 min on), so this benchmark rewards alerting at 0 and scores a correct alert before 0 as a mistake. Early detections like Sloane’s are counted against it.
- Alerts before 0 are not all false: the 48 pre-zero positive episodes in c3d’s test run were never reviewed by a human, and some are real smoke.
- The benchmark scores whole frames. It is not a measure of locating the fire, or of false alerts per camera-hour on clear footage.
- On the previous 11-fire replay with the older segmentation detectors (v6/v7), only 5 of 11 fires had a correctly located alert by +2 min. The new model has not been re-run on that replay.
- Training is unstable. 4 of 9 extra seeds collapsed to chance at the start and were replaced under a rule written beforehand.
- Clouds and moving shadows still cause false alarms. The newest models (c5, c6) add channels for them, and c5 cut pre-zero false alarms by about a third on validation, with slightly lower recall in the first two minutes. They have not been scored on test.
- Plume direction is not fire location, since wind carries smoke away from the source. Location results so far: a 139 m median error on synthetic triangulation, and 6.4 km on one live example.
Source: rwfds results write-up and test ledger, 20–21 Oct 2026. 26 of the 62 test views share a calendar date with a validation view, though none share a date with the training set.
scout · match analysis
scout watches VEX V5RC match livestreams, tracks every robot and game piece, and rebuilds the score. It is checked against the official result of each match.
- 755matches analysed from video (811 played at 8 events)
- 78%match winners called right from video alone
- 89%robots named by team number
- 82 sto analyse a ~136 s match

Replay one match → A best-tracked quarterfinal from Maker Faire OC. The real stream plays with scout's detector boxes over it, next to a top-down field with switchable layers: robot paths and heatmaps, Goal contents, Toggle ownership, scoring events, defensive plays and per-robot stats.
Where it falls short
- A 23-point average miss is too loose for exact scores, so predictions lean on the 4,392 official results rather than the video count alone.
- Pins nested inside a cup are invisible to the detector, so some scoring is never seen.
- An earlier 30-match check, before goals were snapped to the nine real positions, got the winner right only 40% of the time. The 78% figure is the later, larger run.
Status on 6 Oct 2026. Scored against official scores. scout.questionative.dev is invite only.